Cassini attempts to save Lot Summary reports as PDF files in the D:\pdfs directory when "Auto-save Lot Summary report" is enabled in the Options section of the Test Exec. If the Lot Summary report is not needed, RI recommends disabling this option in the Test Exec. If Cassini reports a "path not found" error (see Figure 3), follow the steps to check PMPDF Control Panel. PDF Writer and it's dependancies come pre-installed with ArcaOS in C:\sys\apps\PMPDF and requires GhostScript to be installed in c:\usr\. Please contact RI Support if the issue persists or if this application is missing.
To Check PMDF Control Panel:
- Choose System Toolbox > PMPDF Control panel (see Figure 1)
- Choose GhostScript tab and confirm the config is the same as in Figure 2.
Figure 1: PMPDF Control Panel
Figure 2: PDF Writer > GhostScript tab settings
Figure 3: Example Cassini Error (RiErrorLog, Title=vrtError)
21-Jul-22 03:21:44 pm
{not UI} path not found
DosDLL class(Object)>>error:
DosDLL class>>OS2Error:
Directory>>findFirst:attribute:buffer:
Directory>>contents:
Directory>>filesNamed:
JbPrintLotSummary>>saveAsPDF
JbPrintLotSummary(JbPrintedReport)>>printReport
See also:
CreatePS error Issue https://roos.com/docs/RBEH-BHUKEQ
Installing PDF Writer in eComStation https://roos.com/docs/JBAT-8Z826V
Cleaning PDFs folder on EPC (Test Summary Reports) https://roos.com/docs/RBEH-A4STNB