RI Title
RI logo


This document lists the settings for a handler pod, when shipped from the factory, for a Seiko-Epson handler.



Ri8503A0 Ri8517A0 Ri8517A0 Dual Site (ping pong)
EOTWIDTHSECONDS 0.01 0.01 0.01
BINPOLARITY ACTIVELOW ACTIVELOW ACTIVELOW
EOTPOLARITY ACTIVELOW ACTIVELOW ACTIVELOW
STARTTYPE LEVEL LEVEL LEVEL
STARTPOLARITY ACTIVELOW ACTIVELOW ACTIVELOW
MAXBINS 11 --- ---
MAX SITES --- 1 2
MINWAITSECONDS 0.1 0.1 0.1
MAXWAITSECONDS 15.0 15.0 15.0
EOTDELAYSECONDS 0.001 0.001 0.001
HANDLER Seiko-Epson Seiko-Epson Seiko-Epson


Ri8517A0 Dual Site (parallel)
EOTWIDTHSECONDS 0.01
BINPOLARITY ACTIVELOW
EOTPOLARITY ACTIVELOW
STARTTYPE LEVEL
STARTPOLARITY ACTIVELOW
MAXBINS ---
MAX SITES 2
MINWAITSECONDS 0.1
MAXWAITSECONDS 15.0
EOTDELAYSECONDS 0.001
HANDLER Epson Parallel





Tester to Handler Pin Out:
Signal ROOS Pin Handler Pin
Bin1 1 21
Bin2 2 46
Bin3 3 22
Bin4 4 47
Bin5 5 23
Bin6 6 17
Bin7 7 42
Bin8 8 18
SOT 10 35
GND 12 1,26
EOT 25 37
+5V 11 (attached to tester pin 13)
+5V 13 25

NOTE 1. Pin 11 MUST EITHER be connected to Pin 13 or 14 from the handler pod.
2. For Series 6000 handlers the bin signals need to be changed from 5 to 10.

PrintEmail Link
https://roos.com/docs/DFES-543P7T
ROOS INSTRUMENTS CONFIDENTIAL AND PROPRIETARY
©2001-2024 Roos Instruments, Inc. All rights reserved.