The RIK0220A includes one DUAL SPDT RF module. It is intended to be used with the all RI active series carriers. It is especially easy to use since DC wiring is not required when used in conjunction with the smart carrier. It also helps to reduce fixture complexity where a high level of RF switching is required. High TOIP makes it especially useful for tests requiring this capability.
Note: This module is not a direct replacement for the RIK0058A as the control bits are not the same. Learn More.
Pin Out / Truth Table: | |||||||
Pin# | Function | DS1 | DS2 | DS3 | DS4 | Connector Type | |
P2:12 | +5V | Header Pin | |||||
P2:11 | -5V | Header Pin | |||||
P1:12 | DS1 | Header Pin | |||||
P1:13 | DS2 | Header Pin | |||||
P1:14 | DS3 | Header Pin | |||||
P1:15 | DS4 | Header Pin | |||||
P1:16 | Grnd | Header Pin | |||||
J1 | SW Common | MCX F | |||||
J1-J2 | X | 1 | X | X | MCX F | ||
J1-J3 | X | 0 | X | X | MCX F | ||
J4 | SW Common | MCX F | |||||
J4-J5 | 1 | X | X | X | MCX F | ||
J4-J6 | 0 | X | X | X | MCX F |
When replacing a RIK0058A, update documentation to swap J1 and J3, and J4 and J6. Control codes remain the same, only physical wire connections change.
Device Data:
- 1dB Compression Typical = 30 dBm @ 8GHz
Insertion Loss
Return Loss
Isolation - Common to Off Port
Isolation - Adjacent Ports
S22 Open Port
S22 Closed Port
S22 Closed Port