RI Title
RI logo

Calibration Kit, 40GHz Base Kit

Calibration base kit for +40GHz systems

Part Number: RIK0382A

In Stock:

Estimated Restocking Time: 4-6 weeks

$41,600

The Calibration Kit (Cal Kit) is used while calibrating an RI test system to frequencies of 40 GHz or less. It includes a Digital Multimeter, Power Meter and Sensor, S Parameter Standards, Cables, RF Adapters, RF Attenuators.

A Cassini Cal Kit consists of the Cal Standards RIK0098A. The diagnostic interface kit is sold separately and required for Calibration that includes a Diag/Cal Kit and configuration specific cables, attenuators, and adapters.

The Calibration kit needs to be calibrated annually to NIST standards. RI offers Cal Kit service as RIK0245A 40 GHz Cal Kit Service.



RI usually only issues a NIST traceable calibration certificate only when a preventive maintenance and calibration (PMC) is performed. A calibration is performed when a SyRF Core instrument is repaired or replaced, but a certificate is not issued.

RIKDescription
Product Catalog
023ARI7100A Calibration Kit
Product Catalog
130ACassini 8-Slot Interface Kit
Product Catalog
149ACalibration Standards Kit, Cassini 18 GHz
Product Catalog
150ACalibration Standards Kit, Cassini 40 GHz
Product Catalog
151ACassini 16-Slot Interface Kit

Each RI Cal Kit requires annual calibrations for most instruments. If available, you can use a calibration lab at your facility or one in your local area. If not, some of the components may have to be sent to the manufacturer for calibration. Below is a listing of the Cal Kit components, Vendor Addresses and Web Sites.

Cal Kit Vendor Information: Please refer to the original manufacture's website for a vendor representative in your area.
Power Meter & Sensor
Gigatronics Inc.
4650 Norris Canyon Rd.
San Ramon,
CA 94583-1320 USA
http://www.gigatronics.com/
DMM
Fluke Corporation
6920 Seaway Blvd.
Everett,
WA 98203 USA
http://www.fluke.com/
S Parameters
Anritsu Company
490 Jarvis Dr.
Morgan Hill,
CA 95037-2809 USA
http://www.anritsu.com/

Detailed Item List: (note: Labels subject to change without notice)


RI PartNumber

#

Description

Comments

n/a

1

Cal Certs for all instruments

Deliver to your Cal Lab, note, next cal date based on when the item was pulled from inventory, not what is on the sticker.

ANBM8N5A

1

Cal Kit Maintenance Instructions (DocID RBEH-8K93EC)

Instructions for Maintenance

ELTH8M1A

1

Power Sensor 40GHz, 2.9mm, Gigatronics 80324A w/Cert

1 Yr Cycle

G90H7K2A

1

Adapter, SMA(f)-N(m), 18 GHz

Power Meter to Sensor with SMA

G9AKWA2A

1

Adapter, 2.9mm(f)-2.9mm(f) K Conn

RF Power Cal, Always CLEAN and tighten nut, DO NOT ROTATE adapter

GGFEGW2B

1

Cable, RIFL3-RIFL2, 84in

Power Meter control

GM73Y02A

1

Adapter, SMA(m)-SMA(f), 20 GHz 

RF Power Cal, Always CLEAN and tighten nut, DO NOT ROTATE adapter

M5PJG21A

1

Cable, Conformable, SMA(m)-SMA(m) 11"

Use caution when bending cable to fit, no sharp kinks

M5WNBC1A

1

Cable, BNC(m)-BNC(m) 36in

WF DC Cal via tester's FIX block

M6LPX11B

4

Vial W/Cap, 20ml

Storing Adapters

M7CJ222A

1

Spanawave Power meter 8541C W/Cert

1 Yr Cycle

MBH0VH1B

4

Adapter, #12 PKZ-SMA(f) Custom, Cal/Diag

<=40 GHz RF Cal, any RF TIM Blocks in Diag/Cal Plate

MFN6ZK1B

1

Multimeter Fluke 87v Series 5, w/Cert

1 Yr Cycle

MFT08S1A

1

AC Line Cord IEC C13(f)-C14(m), 6ft

Power Meter DC

MJHEHY3A

1

GPIB Cable  0.5m M-M/F (90 degrees)

Power Meter control

MM9NAK6F

1

Case, Transit, Cassini Cal Kit

Protects all Cal instruments

MMB7GT5A

1

Banana to ez-hook mini gripper leads, 24" 1 red 1 black (set)

DC Calibrations, DMM

MMF72X1A

1

Adapter, BNC(f) to SMA(m)

WF Cal, Always CLEAN and tighten nut, DO NOT ROTATE adapter

MMFPB91A

1

Adapter, BNC(f) to Dual Banana Plug

WF Cal

MNXEHK4A

1

Cable, Gigatronics Power Sensor-N(m)

1 Yr Cycle

RI8502B0

1

RI8502B RIFL-GPIB POD Isolated

Power Meter RIFL Control Cassini AUX H-Port