RI Title
RI logo

20/40 GHz Calibration Standards Kit

Part Number: RIK0150A

In Stock: 0

Estimated Restocking Time: Contact Factory

$48,730

The Calibration Kit (Cal Kit) is used while calibrating an RI test system to frequencies of 40 GHz or less. It includes a Digital Multimeter, Power Meter and Sensor, S Parameter Standards, Noise standard, Cables, RF Adapters, RF Attenuators. A Cassini Cal Kit consists of the Cal Standards RIK0098A. The diagnostic interface kit is sold separately and required for Calibration.

The Calibration kit needs to be calibrated annually to NIST standards. RI offers Cal Kit service as RIK0082A (for 20 Ghz cal kits)



RI usually only issues a NIST traceable calibration certificate only when a preventive maintenance and calibration (PMC) is performed. A calibration is performed when a major physical instrument is repaired or replaced, but a certificate is not issued.

RIKDescription
Product Catalog
023ARI7100A Calibration Kit
Product Catalog
130ACassini 8-Slot Interface Kit
Product Catalog
149ACalibration Standards Kit, Cassini 18 GHz
Product Catalog
150ACalibration Standards Kit, Cassini 40 GHz
Product Catalog
151ACassini 16-Slot Interface Kit


Each RI Cal Kit requires annual calibrations for most instruments. If available, you can use a calibration lab at your facility or one in your local area. If not, some of the components may have to be sent to the manufacturer for calibration. Below is a listing of the Cal Kit components, Vendor Addresses and Web Sites.

Cal Kit Vendor Information: Please refer to the website for a vendor representative in your area.
Power Meter & Sensor
Gigatronics Inc.
4650 Norris Canyon Rd.
San Ramon,
CA 94583-1320 USA
http://www.gigatronics.com/
DMM
Fluke Corporation
6920 Seaway Blvd.
Everett,
WA 98203 USA
http://www.fluke.com/
S Parameters
Anritsu Company
490 Jarvis Dr.
Morgan Hill,
CA 95037-2809 USA
http://www.anritsu.com/
Noise Source
NoiseCom
E. 64 Midland Ave.
Paramus,
NJ 07652 USA
http://www.NoiseCom.com/

Detailed Item List: (note: Labels subject to change without notice)

RI PartNumber
#
DescriptionComments
n/a
1
Cal Certs for all instrumentsDeliver to your Cal Lab, note, next cal date based on when the item was pulled from inventory, not what is on the sticker.
ANBM8N5A
1
Cal Kit Maintenance Instructions (DocID RBEH-8K93EC)Instructions for Maintenance
MNXEHS4A
1
USB Stick (2GB) with Cal Kits Standards Cal dataImport .GZP to use Cal Kit definition
MFN6ZK1B
1
Multimeter Fluke 87v Series 51 Yr Cycle
MMB7GT5A
1
Banana mini gripper leads, 24in 1 red 1 black (set)DC Calibrations, DMM
MMFPB91A
1
Adapter, BNC(f) to Dual Banana PlugWF Cal
M5WNBC1A
1
Cable, BNC(m)-BNC(m) 36inWF DC Cal & DC power for Noise Source via tester's FIX block
M7CJ222A
1
Gigatronics Power Meter 8541C1 Yr Cycle
MFT08S1A
1
AC Line Cord IEC C13(f)-C14(m), 6ftPower Meter power from AUX Rack
MNXEHK4A
1
Cable, Gigatronics Power Sensor-N(m)1 Yr Cycle
ELTH8M1A
1
Power Sensor 40 GHz, 2.9mm, Gigatronics 80324A1 Yr Cycle
G90H7K2A
1
Adapter, N(m)-SMA(f), 18 GHzAlways CLEAN and tighten nut, DO NOT ROTATE adapter
RI8502B0
1
RI8502B RIFL-GPIB POD IsolatedPower Meter control
GCBCRS2A
1
Cable, GPIB(m)-GPIB(m), 0.5mPower Meter control
GGFEGW2B
1
Cable, RIFL3-RIFL2, 84in (2m)Power Meter control
MJ7F5T3A
1
Cal Standards 40GHz, K Conn (2.9mm), Anritsu SC77772 Yr. Cycle
MBH0VH1B
4
Adapter, #12 PKZ-SMA(f) Custom, Cal/Diag<=40 GHz RF Cal, any RF TIM Blocks in Diag/Cal Plate
MU3JU94A
1
Noise source .1-40 GHz, 20dB ENR, Micronetics NS346Ka-CS32 Yr. Cycle
Y000BUA1
1
Noise Source Cal Adapter, FIX BlockConnect to tester's FIX Port and K05
MCTR861A
1
LNA, Isolated, 12-20 GHzRF System Cal
MMF72X1A
1
Adapter, BNC(f) to SMA(m)WF Cal, Always CLEAN and tighten nut, DO NOT ROTATE adapter
M5PJG21A
1
Cable, Conformable, SMA(m)-SMA(m) 11"Use caution when bending cable to fit, no sharp kinks
GM73Y02A
1
Adapter, SMA(m)-SMA(f), 20 GHz RF Power Cal, Always CLEAN and tighten nut, DO NOT ROTATE adapter
G9AKWA2A
2
Adapter, K 2.9mm(f)-K 2.9mm(f)40+ GHz RF Cal, VERY DELICATE: Always CLEAN and tighten nut, DO NOT ROTATE adapter
MRLWGX1A
1
Cable, 40 GHz Loopback, K Conn 2.9mm (3dB + 6” Semi-Rigid + 3dB)Curve 180° to use, store curved (G9AKW02A with MLYM9G1A)
MM9NAK6A
1
Case Transit cal kit Cassini 16Protects all Cal instruments

Related Documents:


SubjectTopic(s)CategoriesLast Modified
Product Docs
Calibration Kit Maintenance for CassiniAdmin,Test-planMaintenance,Calibration,Calibrations,CalKit01/25

Item Ref Part Number QTY Description Category Qty in Stock
1MRLWK84A1Cal Kit 40 GHz <>*Mntnnc
BOM Refreshed:05/11/2020 06:23 PM