RI Title
RI logo


The CASSINI (or RI7100C) ATE systems can operate in a wide range of environmental conditions. Depending on the system configuration, some specifications may not apply or have individual requirements. No special plumbing or ventilation is required. Customer must provide items designated with "NOT PROVIDED" label. All values are subject to change without notice.

    RI8568B "Cassini 16" Infrastructure:
      • Height: 1,745 mm (68.7 in.)
      • Depth: 1,151 mm (45.3 in.)
      • Width: 843 mm (33.2 in.)
      • Max Shipping Weight: 250 Kg (550 lbs.)
      • Electrical Plug: NEMA 5-20P Plug Provided (Cassini side is IEC320-C19)
        Other Plug Types: Cut off NEMA provided plug and use pig-tail plug adapter. NOT PROVIDED
      • FunctionLabelColor, IEC
        Protective Earth, GroundPEgreen-yellow
        NeutralNblue
        Line, single phase, HotLbrown or black
        • 20 AMP service
        • Minimum: 0.15 kVA
        • Maximum: 0.75 kVA
        • Aux Rack Maximum: 1.2 kVA (300 VA per Source)
    RI8611A "Cassini V93K CTH" Infrastructure:
      • Height: 0.256 m (10.08 in.)
      • Depth: 1.056 m (41.61 in.)
      • Width: 0.754 m (29.72 in.) Includes TIMs
      • System Weight: 79 Kg ( 174 lbs.) (8 TIMs)
      • Max Shipping Weight: 105 Kg (230 lbs.)
      • Electrical:
        • EC320-C13(f) [PSU Cassini side requires C14(m)]
        • Input AC Power Requirements: 3.8A/115VAC or 2A/230VAC
        • Max Inrush Current: 95A/115VAC or 120A / 230VAC

    RI8591A "Cassini SPYDER" Infrastructure: (preliminary - subject to change)
      • Height Min/Max: 741.9/1097.3 mm (29.2/43.2 in.)
      • Depth: 576.3 mm (22.7 in.)
      • Width: 772.7 mm (30.4 in.) Includes TIMs
      • System Weight: 79 Kg ( 174 lbs.) (8 TIMs)
      • Typical/Max Shipping Weight: 32/45 Kg (70/100 lbs.)
      • Electrical:
        • Plug type: NEMA 5-15P (Cassini side is IEC320-C13)
        • Minimum: 0.15 kVA
        • Typical: 0.40 kVA
        • Maximum: 3.6 kVA (IEC C13 pass through)
    All Electrical Input:
      • Input voltage and frequency ranges supported automatically.
        • 220 V or 110 V
        • 50 Hz or 60 Hz AC, Single Phase Sine-wave input.
    NOTE: The System Controller and Touch UI (RI8583A) option uses the power supply from the tester. Depending on the monitor type, it may use the AUX rack power supply (if available) or need an additional outlet.

    Fixture: (for docking with a Handler or Prober)

      • Always consider the Fixture height when determining minimum clearance of the Test Head.
      • Height: 195.6 mm (7.7 in.) - includes clearance for alignment pins (Varies based on Model/Design)
      • Depth: 266.7 mm (10.5 in.)
      • Width - 16 slot test head: 558.8 mm (22 in.)

    Environment:
      • Operating Air Temperature: 10° to 35°C (50° to 95°F)
        For best calibration performance, a consistent ambient room temperature of ± 5°C is recommended.
      • Humidity: 8% to 80%
    Handler/Prober:
      • Docking options based on Handler/Prober Type: Hard dock (RIK0070A, HNDPLATE), Soft dock (Cables)
      • Handler "Pod" per handler/prober per system: GPIB (RIK0263A), Serial (RIK0266A), Parallel (RIK0267A) - N/A for RI8611A
        Requires factory RI configuration and programming, send detailed handler control logic to "[email protected]" prior to ship date.
      • Handler Pod Interface Cable: Parallel 25 Pin Female D-Sub (Custom MFSHLX1A), Serial Female RS232, or GBIP cable. NOT PROVIDED

    IMPORTANT Electrical Ground:


      It is essential to maintain solid ground between the handler and the Roos system rack. This helps to prevent Device Under Test (DUT) damage and damage to the Roos handler interface.
      • The green ground wire in the side/back of the Infrastructure should be connected directly to the handler ground. This should be inspected each time a handler is connected to the test system by the operator.
      • The ground should be checked each time a handler is connected. Measure both AC voltage (must be less than 50 millivolts) and ground resistance (which should be less than 5 ohms) between the tester ground and the handler ground.
        Note: Measuring negative resistance is a sign that DC or AC voltage is present. Any of these conditions would indicate failure to ground and should be corrected prior to testing parts.
    Workstation Desk:
      • Surface not needed for Cassini 16 (RI8568B) with Aux Rack, Touch UI (RI8583A) or Arm UI (RI8599A) or Cassini V93K CTH (RI8611A)
      • System Controller EPC TIM requires standard CAT-5 RJ45 ethernet network cable to integrate with network and access Guru Server.
      • Monitor requires power plug (varies based on monitor C13 or C7). If available, can be supplied by RI8568B's AUX rack.
      • Workspace (cart) is needed to hold monitor, keyboard and mouse. NOT PROVIDED
      • Workspace must be located within network cable reach of the System Controller (adjacent to system)

    Compressed Air: ONLY RI8568B Cassini 16

      • Input Pressure 65-120 PSI (regulated to 90 psi)
      • System Connector Type: Quick Disconnect US Industrial/Milton MIL-C-4109 Male (preferred)
        4109 Male @ Facility Cassini System
      • Adapters included with system: (MPSNYT5A)
        • THREAD NPT 1/4" Female @ Facility to Quick Disconnect on tester (option #1)
          Facility 1/4" NPT threadSystem Connector
        • HOSE 8mm or 5/16 in.: Barbed hose adapter and clamp with 1/4" NPT male thread (option #2)
          Hose @ Facility Adapter to Cassini System (thread)

    Additional information:
    Database 'Product Docs', View 'All Documents', Document 'Cassini Footprint - Cassini 16 Infrastructure'Cassini Footprint - Cassini 16 Infrastructure
    Product Docs
    Product Docs
    Cassini Footprint - Cassini SPYDER 8 Infrastructure
    Cassini Footprint - Cassini V93K CTH Infrastructure


    Database 'Product Docs', View 'Manuals\Cassini Manual\Table Of Contents', Document 'Site Preparation Guidelines for Legacy CASSINI and RI7100A&C' Legacy platform (RI7100A, RI7100C, Cassini Small, Cassini Large) Site-Preparation Guidelines.

    PrintEmail Link
    https://roos.com/docs/RBEH-6Z5482
    ROOS INSTRUMENTS CONFIDENTIAL AND PROPRIETARY